Nordyne iSEER FG7T Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Aquecedores e fervedores de água Nordyne iSEER FG7T. Nordyne iSEER FG7T User's Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 8
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
• i SEER: Energy efcient brushless DC (ECM) motor
givesupto1SEERpointefciencygainincooling.
• 100% fired and tested: Allunitsandeachcomponent
aretestedonthemanufacturingline.
• Best packaging in the industry: Uniquecorner post
designassuresproductwillarrivetothehomeownerdent
free.
• Low Boy Height:Easytoapplyinlowceilingapplications,
workswellwithtallerhighSEERcoils,easiertohandle
andinstall.
• Tubular primary heat exchanger: Heavy gauge
aluminizedsteelheatexchangerassuresalonglife.
• 30 second blower delay at start-up:Assuresawarm
ducttemperatureatfurnacestart-up.Adjustableblower
offsettings(60,90,120and180seconds).
• 30 second post purge: Increases life of heat
exchanger.
• Hot surface igniter: Innovativeapplicationofasilicon
nitrideigniter.UtilizesprovenSmartlite
®
technology.
• Color coded wire harness: Designed to fit the
components,all with quick-connectttings forease of
serviceandreplacement.
• High static blowers:Allmodelsequippedwithhighstatic
blowers.
• 90 second cooling cycle blower-off delay (TDR):
Increases cooling performance when matched with a
NORDYNEcoil.
• Flexible category I venting system: May be vented
withdedicatedventingsystemorcommonventedwith
othercategoryoneappliances.
• Variable speed blower kit: Upgradabletofullvariable
speedwithkit.
• LP convertible:Simpleburneroriceandregulatorspring
changeforeaseofconvertibility.
• Diagnostic lights for easy troubleshooting without
counting flashes: Dedicated light for ame signal
strengthand2lightsincombinationtoindicateallother
faultcodeswitheasytorecognizestateswithoutcounting
ashes.
• Integrated control board: Incorporatesconnectionsfor
electronicaircleaner,humidierandtwinning.
• Two piece door design: Enhancesfurnaceappearance
and uses captured screws to prevent loosing door
screws.
• Blower Compartment: Insulated for ultra quiet
operation.
• 2 Stage Inducer: Optimizesefciencyonrststageheat
andreducessoundlevels.
Induced Draft - 80 + AFUE
Input 60,000 - 140,000 Btuh
FG7T (A and K Series)
Two Stage, Fixed Speed,
High Efficiency Upflow/Horizontal
and Downflow Gas Furnaces
The high efciency gas furnace may be installed free
standinginautilityroom,basement,orenclosedinan
alcoveorcloset.The roundedcornerjacketprovidesa
pleasing“applianceappearance.”DesigncertiedbyCSA
forapplicationinCanadaandtheUnitedStates.
FEATURES and BENEFITS
, Smartlite
®
–10Yearall-partswarranty.
–10YearQualityPledgeto replace theunitiftheheat
exchangerfailswithintherst10yearsofoperation,to
theoriginalowner.
–Consumer product registration required for 10 year
AllPartsWarrantyandQualityPledgewithinalimited
periodoftimeaftertheinstallation.Seecurrentwarranty
documentorvisitourconsumerwebsiteforwarranty
details.
–Whenregistered,thisproductisupgradedtoalimited
lifetimeheatexchangerwarranty.
WARRANTY
TECHNICAL
SPECIFICATIONS
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1 - FG7T (A and K Series)

• i SEER: Energy efcient brushless DC (ECM) motorgivesupto1SEERpointefciencygainincooling.• 100% fired and tested: Allunitsandea

Página 2 - GAS FURNACE COMPONENTS

2Downflow Gas FurnaceGAS FURNACE COMPONENTSUpflow/Horizontal Gas Furnace1 2 345 6 78968315110161145712132141 2 345 6 78151676893114213121410511. Blower

Página 3 - DIMENSIONS

3DIMENSIONSFG7TA 80+ High Efficiency Upflow/Horizontal SeriesFG7TK 80+ High Efficiency Downflow SeriesD23 1/2A232834 1/215125 3/81 5/8 X 3 1/2HOLE FOR GA

Página 4 - BLOWER PERFORMANCE - FG7TA/TK

4BLOWER PERFORMANCE - FG7TA/TKFG7TA/TK - 80% AFUE, Two Stage Gas FurnaceModel NumberHeating Input (Btuh)Motor Switch SettingExternal Static Pressure (

Página 5

5BLOWER PERFORMANCE - FG7TA/TK ContinuedNotes:1.MotorSwitchSettingsareforheatingspeedsusingHEATswitches1,2,3,&4andcoolingspeeds

Página 6

6BLOWER PERFORMANCE - FG7TA/TK ContinuedFG7TA/TK - 80% AFUE, Two Stage Gas FurnaceModel NumberHeating Input (Btuh)Motor Switch SettingExternal Static

Página 7 - SPECIFICATIONS

7MODEL IDENTIFICATION CODEDesignSeriesA=80%Upow/HorizontalC=92.1%/95.1%Upow/HorizontalK=80%DownowL=92.1%/95.1%DownowQ=96.4+%AF

Página 8 - ACCESSORIES

FG7TA/TK KITS Description SKUFixedspeed-to-variablespeed 904880"A"Cabinetdownowsubbasekit 902974"B","C",&quo

Comentários a estes Manuais

Sem comentários